Currencies

Categories

Who's Online

There currently are 100 guests online.

AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay

(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
(image for) AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S delay
  • Model: PIR-Sensors-110-250v-TB
  • Shipping Weight: 0.3 lbs

(image for) Ask a Question

$6.16

Qty Discounts Off Price
1-49
$6.16
50-99
$5.85
100-199
$5.54
200-399
$5.24
400-799
$4.93
800+
$4.62
 
Add to Cart:
AC110V~250V, 1W~200W Infrared PIR Sensor Switch, 10~360S time delay adjustable,  Automatic Infrared PIR Motion Sensor Switch For lighting light 
Summarization:
 
•The human body is an infrared detection sensor switch controller, the use of infrared detection control the load of the switch.
•Users according to actual needs, the human body sensors installed in the appropriate environment
 
 
Technical parameters:
•Working temperature: -20 to +60 
•Supply voltage: AC100V~AC250V
•Sensing distance: PIR 0~ 8 M, Lux sensor adjustable from 5 lux to 500 lux. So that you can set it work all the day or work on in night only
•Ham should angle: 110~140 degrees.
•External dimension:     mm
•static power consumption: 0.0088w
•output load 1w~200w LED bulbs, CFL bulb and incendescent bulb
 
Direction for Use
 
•Connect the load wire at first, following by the power wire; Please ensure short circuit can not occur between connecting wire before you turn on the power;
•when the detected light up when the load was light, when people leave after 10~360 seconds (adjustable), load lights automatically turn off.
•The controller signal output line and input line should be connected correctly.   
  

Your IP Address is: 18.218.190.118
Copyright © 2024 www.ledlightbulb.net/. Powered by Zen Cart